SHINVA Medical Instrument Co., Ltd. (Shandong)
Products
Contact Us
  • Contact Person : Mr. Lee Oliver
  • Company Name : SHINVA Medical Instrument Co., Ltd. (Shandong)
  • Tel : 0086-533-3587720
  • Fax : 0086-533-3587722
  • Address : Shandong,Zibo,No. 7 Taimei Road, Zibo New & Hi-tech Zone, Shandong, P.R.CHINA
  • Country/Region : China
  • Zip : 255086

Famous Mark,SL-IE Digital Radiotherapy Simulator

Famous Mark,SL-IE Digital Radiotherapy Simulator
Product Detailed
Radiotherapy simulator is a kind of necessary equipment for tumor patients to examine and confirm their treatment plan before r

  SL-IE Digital Radiotherapy Simulator

  Brief introduction:  Radiotherapy simulator is a kind of necessary equipment for tumor patients to examineand confirm their treatment plan before radiotherapy, which with high demand for the imagedefinition, technique specification, isocenter accuracy etc.  Model SL-IE radiotherapy simulator is the latest digital simulator we developed, supportDICOM RT interface, and can be fulfilled the digital data transferred through Internet to theradiotherapy unit directly.

  I.Main Features: 1.High precision technological unders isocenter precision≤1mm. 2.HD image: image resolution is 16LP/cm. 3.Transform the image with DICOM RT interface. 4.Imported 500mA X-RAY tube, imported high frequency X-RAY generator and imported HDmonitor. 5.THALES 12image intensifier and imported HD video camera. 6.Unsymmetrical field simulation technology is used to meet different position requirementfor tumor patients. 7.Precision PSA is stable and reliable. 8.Two control modes of computer and console can be chose. 9.Multi image processing function.

 Main specifications

   1.Parameters of Simulative Locating:                                 

  (1) SAD: 700-1200mm,continuously adjustabl

  (2) Gantry rotation range: ±185°(SAD≤1000mm) ±135°(SAD1000mm)  (3) Isocenter tolerance:≤1mm  (4) Therapeutic field:     1)Symmetric field: SAD=800mm 16mm×16mm320mm×320mm                                SAD=1000mm 30mm×30mm400mm×400mm     2)Unsymmetric field: SAD=1000mm single line -100mm200mm  (5) Rotation range of collimator: ±100°  (6) Diagnostic table:  Longitudinal movement: ≥900mm                                 Lateral movement: ±200mm                                 Vertical movement: 750mm1300mm                                 Isocentric rotation: ±100°  2.Parameters of X-RAY:

 (1) Fluoroscopy: 40kV~125kV 0.5mA~6mA (2) Radiography: 40kV~125kV 25mA~500mA

  3.X-TV system: (1) Image resolution is better than 16LP/cm (2) With automatic control of brightness.Standard Configuration1. 500mA X-ray tube2. CPI 50KW high frequency X-ray generator and control equipment(Include HLFIBS)3. Imported 12" QX high contrast Image Intensifier4. Imported CCD Camera 1k×1k5. Digital image system6. DICOM RT system7. 18" LCD (one, main monitor)8. 19" high definition Flat Display (one, Assistant monitor)9. 15" LCD (one)10. Industry Control Computer (one)11. Laser Printer (one)12. Semiconductor Laser Orientation (one set, three pieces)13. Optical Distance Indicator, Mechanical Distance Indicator (one each)14. Precision Table (one)15. Asymmetry Collimator

Famous Mark,SL-IE Digital Radiotherapy Simulator



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.